192

Note: The outer sheath material, color and printing information of the optical cable can be customized according to customer requirements

192 Cores Armored Cable
ItemUnitDescription
192 cores(8 subunitsEach has 24 cores)Outer diametermm2.3±0.1
Thicknessmm0.25±0.1
Material/LSZH
Color/White
Fiber diameterμmΦ250±15
Fiber count24 coresThe first 12 cores are: blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, green; The last 12 cores add a black color ring on the basis of the first 12 cores (where the corresponding black fiber is changed to natural color, and no color ring is added) the distance between the color rings is required to be no more than 100mm. The rest comply with the provisions of GB 6995.2-86 Part 2: Standard color
Armor tubeMaterial/Stainless steel
Outer diametermm11.1±0.1
Outer jacketOuter jacket material/TPU
Outer jacket colormmBlack (PANTONE Black 3C)
Outer jacket thicknessmm1.4±0.15
Outer jacket diameter (D)mm14.4±0.3 or finer
OthersTensile material/Aramid yarn
Strength member material/FRP
Min. bending radius/5D
Cable net weightkg/km≤Provided by supplier

Optical performance

Max.Cabled Attenuation(db/km)850nmdB/km≤3.0
1300nmdB/km≤1.0
ReferenceGJB1427B-2013

Mechanical performance

NO.TechnicalparameterPerformanceindexReferenceNote
1TensileTensile :short-term 1500N,the load time is not less than 1min. The sample should have no crack, or fracture, or the elongation should not be greater than 2%, and the change in light transmission property during and after the test should not be greater than 0.5dB.GJB1428B-2009 3.5.1.1
2FlattenFlatten:3000N/100mm,the load time is not less than 1min. The sample should have no crack, or fracture, or the elongation should not be greater than 2%, and the change in light transmission property during and after the test should not be greater than 0.5dB.GJB1428B-2009 3.5.5
3CrushWeight of drop hammer 0.5kg, cycle times 30 times. The sheath should have no cracks, or other damage that may cause the penetration of the sheath, and the change in light transmission performance should not be greater than 0.5dB.GJB1428B-2009 3.5.8
4BendingThe cycle rate is 30 times per minute, and the number of cycles is 500. The sheath should be free of cracks. During and after the test, the change of light transmission property is not more than 0.5dB.GJB1428B-2009 3.5.4
5TwistThe test load is 100N and the number of cycles is 500 times. There should be no softening, surface damage (no crack, cor other damage that may cause sheath penetration) or damage to identification marks. During and after the test, the change of light transmission property is not more than 0.5dB.GJB1428B-2009 3.5.6

Environmental performance

NO.TechnicalparameterPerformanceindexReferenceNote
1Temperature shockTemperature:-40℃~+85℃;Limit temperature duration: 2h each;Number of cycles: 5Eligibility criteria: the sheath should not be softened, surface damage or identification mark damage, the cable diameter change should not be greater than ±10%. During and after the test, the change of light transmission performance is not more than 0.5dB/Km.GJB1428B-2009
2TemperaturecycleTemperature:-40±2℃→+25±2℃→+85±2℃→+25±2℃Limit temperature duration: 4h each;Number of cycles: 5Eligibility criteria: the sheath should not be softened, surface damage or identification mark damage, the cable diameter change should not be greater than ±10%. During and after the test, the change of light transmission performance is not more than 0.5dB/Km.GJB1428B-2009
4Mold testThe test methods were carried out according to GJB 150.10A-2009 “Military Equipment Laboratory Environmental Test Method Part 10 Mold Test”.a) Duration of the test: 28d;b) Test strain: strain group 2;c) The surface mildew grade of the tested product after mold test should not be more than grade 2.GJB150.10A-2009

Flammability flame retardant meets

GJB1428B-2009 Requirements

20150827162119_29649-37Excellence rodent resistence20150827162134_93787-40Anti-torsional
20150827162158_19402-36Fiber to home20150827162211_16684-35Tensile
20150827162222_54771-23Horizontal wiring20150827162233_19185-26Duct
20150827162245_41439-36Vertical wiring20150827162304_97469-31Direct-buried
20150827162319_81378-39Base station stretching20150827162329_52312-27Overhead pipeline
20150827162340_34027-24Equipment room deployment20150827162350_21731-25100% Waterproof
20150827162401_19456-26Field deployment20150827162410_57491-36100% Fireproof
ItemUnitParameter
Fiber typeTensile 0M3 Multi-mode10G,300m
Geometrical features
Cladding diameterμmΦ125.0
Cladding out of roundness%≤6
Coat unroundness%≤2
Core/cladding concentricity errorμm≤1
Coating diameterμmΦ245±10
Coating/cladding concentricity errorμm≤12.5
Transfer characteristic
Attenuation850nmdB/km≤3.0
1300nmdB/km≤1.0
Min. bandwidthOverfilled width(850nm)MHz.km≥1500
Overfilled width(1300nm)≥500
Effective modal bandwidth (850nm)≥2000
Bending attenuation(radius:7.5mm,2 circles)Wavelength 850nmdB≤0.2
Wavelength 1300nmdB≤0.5
Bending attenuation(radius:15mm,2 circles)Wavelength 850nmdB≤0.1
Wavelength 1300nmdB≤0.3
Bending attenuation (radius:37.5mm,100 circles)Wavelength 850nmdB≤0.5
Wavelength 1300nmdB≤0.5
NA/0.200±0.015
Mechanical features
Fiber strengthGPa0.69
Dynamic fatigue parameter/≥20
Peeling power of coating powerN5~13.3
Other properties of fibers not listed in the table comply with GJB1427B standards, unless otherwise specified.